Refrigerated type Compressed Air Dryer
As the temperature of air reduces, its
water vapour holding capacity comes down drastically. This principle is
employed in Refrigerated type dryers. Compressed air is cooled by
refrigeration system thereby reducing its watervapour holding capacity.
Water vapours above the holding capacity at reduced temperature condense
into water droplets and are removed in water separator. The resultant
compressed air becomes dry to pressure dew point equal to its reduced
temperature (generally around+2°C to +8°C). As long as the
temperature of compressed air, as it travels through the system does not
fall below the dew point temperature produced in the dryer, no more
water vapours will condense into troublesome liquid in downstream air
lines.
Features:
- Lower energy consumption compared to other type to dryers for
equivalent degree of dryness.
- Heat exchangers maintain high degree of heat exchange efficiency
and lower pressure drop through out life of dryer.
- Consistent degree of dryness over a wide range of flows and
operating conditions.
- Units supplied in rugged Industrial cabinet prewired and piped
for easy installation.
- Safety interlocks for compressor, fans etc.
- Easy access to all parts.
- Unit built under strict quality control procedures to maintain
consistently high product quality. Requires low maintenance during
its life.
Model Chart:
| Model |
Rated flow capacity Nm3/hr (cfm) (1) |
Maximum working Pressure (Kg/cm2g) (2) |
Inlet / Outlet Connections (3) (4) |
Dimensions (mm) |
Weight (Kg) |
| Length |
Width |
Height |
| SR-0015 |
25(15) |
12 |
1/2" BSP |
600 |
450 |
800 |
35 |
| SR-0025 |
42(25) |
12 |
1/2" BSP |
600 |
450 |
800 |
45 |
| SR-0045 |
76(45) |
12 |
1/2" BSP |
650 |
500 |
800 |
90 |
| SR-0075 |
127(75) |
12 |
1" BSP |
700 |
600 |
1000 |
100 |
| SR-0100 |
170(100) |
12 |
1" BSP |
750 |
650 |
1100 |
115 |
| SR-0150 |
255(150) |
12 |
1 1/2" Flanged |
800 |
650 |
1100 |
150 |
| SR-0200 |
340(200) |
12 |
2" Flanged |
900 |
650 |
1100 |
245 |
| SR-0300 |
510(300) |
12 |
2" Flanged |
1200 |
750 |
1150 |
265 |
| SR-0400 |
680(400) |
12 |
3" Flanged |
1200 |
850 |
1150 |
285 |
| SR-0500 |
850(500) |
12 |
3" Flanged |
1400 |
750 |
1200 |
530 |
| SR-0600 |
1020(600) |
12 |
3" Flanged |
1600 |
750 |
1200 |
600 |
| SR-0800 |
1360(800) |
12 |
4" Flanged |
1600 |
900 |
1200 |
850 |
| SR-1000 |
1700(1000) |
12 |
4" Flanged |
1600 |
1100 |
1200 |
975 |
| SR-1200 |
2040(1200) |
12 |
4" Flanged |
1600 |
1300 |
1200 |
1100 |
| SR-1500 |
2550(1500) |
12 |
4" Flanged |
2000 |
1250 |
1600 |
1650 |
| SR-2000 |
3400(2000) |
12 |
6" Flanged |
2000 |
1500 |
1650 |
1900 |
| SR-2500 |
4250(2500) |
12 |
6" Flanged |
2200 |
1700 |
1700 |
2200 |
| SR-3000 |
5100(3000) |
12 |
6" Flanged |
2200 |
1900 |
1700 |
2500 |
| SR-3500 |
5950(3500) |
12 |
6" Flanged |
2500 |
2000 |
1800 |
3000 |
| SR-4000 |
6800(4000) |
12 |
8" Flanged |
2600 |
2200 |
1900 |
3400 |
| SR-5000 |
8500(5000) |
12 |
8" Flanged |
2600 |
2500 |
2000 |
3700 |
- Rated flow capacity is based on compressed Air pressure of 7kg/cm2g,
Inlet temp of 40°C and outlet pressure dew point of 2°C. For
any change in pressure and dew point, ask for our sizing chart or
consult our application Engineers.
- Dryers with higher maximum working pressure are available on
request.
- Inlet/Outlet connections indicated are standard. For any
different connections, please specify.
- Flanged connections shall be as per ANSI 150#RF.
Model Designation

|